Daimler
This document describes the changes in the software since the last release. Please check which parts are affecting your environment carefully.
Title | Description |
---|---|
Service-stopping and checking | EWA Installation Manager now stops all EWA-services and checks if any of the internal processes are still running (tomcat.exe, tbmux32.exe, tbkern32.exe). Installations/Updates will only run successfully if all services and processes could be stopped correctly. Any thirdparty Tomcat- or Transbase-process that is running within the EWA-installation-directory should be stopped prior to updating. |
Problem with managing of Windows services | A problem with managing Windows services had been adressed. Now Installer and AdminTool are no longer using sc.exe for managing services. |
EWANAPI | EWANAPI has been updated to fix a bug on Star Diagnosis when reading the appserv_user.ini-file from SDnetControl. On Star Diagnosis and XENTRY Connect the EWANAPI will check for appserv_user.ini and (if user.ini not available) for appserv.ini. The paths have to be added in registry for EWANAPI to find them. |
EWAnAPI News Decoder | EWAnAPI News Decoder (Token acceptor) does not need to be replaced. |
AdminTool changes | Several issues have been fixed for AdminTool. Also some new features are included in this update for the AdminTool:
|
Dataspooler | A new version of dataspooler has been integrated. It is a complete new implementation of dataspooler. |
Market/Manufacturer Notes | When a user is to be deleted, the market/manufacturer notes of this user should not be deleted at the same time. They should still be available for other users to read. This has been implemented now. |
Web Service | A new Web Service has been added to determine access rights of a user. This web service needs to be enabled in core_cfg.xml by setting a password in "AccessRightsWS". Without password this service will not run, so by default it is turned off. |
Versioning | The versions of the following jar-files have been incremented in order to update certificates:
Also, the versioning of the CommonLic.dll has been fixed. |
Title | Description |
---|---|
EWAnAPI | Bugfix for StarDiagnosis and XENTRY Connect devices. |
Tomcat server | No changes on server-installation. |
Server JRE | No changes on JRE. |
AdminTool JRE | No changes on AdminTool JRE. |
Client-Download-JRE | No changes on Client-Download-JRE. |
ClientTools | The ClientTools have changed, due to some minor fixes. |
ClientChecker | No changes for EWA ClientChecker. |
EWAnAPI News Decoder | EWAnAPI News Decoder is the same as before and does not need to be exchanged. |
Database-Changes | No changes in database. |
Dataspooler | A new version of dataspooler has been integrated. |
Title | Version |
---|---|
EWAnAPI | 1.18.35.164 |
CommonLic | 1.2.164.0 |
AdminTool | 2.18.164.0 |
Client-Download-JRE | Sun Java SE 6 Update 27 |
AdminTool JRE | 1.6.0_27 |
Private-JRE | Java Runtime Environment 6.0 (1.6.0_16) together with a cryptographic classloader |
Client-Tools | 2.140 |
Ewacore | 1.18.164.0 |
Tomcat | Tomcat 6.0.32 (Apache Group) |
ClientChecker | 1.18.164.0 |
QC | Title | Description |
---|---|---|
Migrate-Config für Secure Linkout | The configuration for secure linkout was not migrated during EWA update. So the values were replaced by default values after each update. This has been fixed, so that the configured values are migrated during software-update now. | |
4108 | [QualityCenter] - Defect: [4108] - Status: [Approved] - Summary: [Spooldaten-Download-Backlinks in WIS sind nach Update verschwunden] | The configuration value for direct link to download-area has been fixed to be migrated. So the configured value is migrated during software-update now. |
QC | Severity | Title | Description |
---|---|---|---|
4119 | Medium | [QualityCenter] - Defect: [4119] - Status: [New] - Summary: [Properties im Admin Tool (alt) werden nach dem Update nicht angezogen] | The installation of old AdminTool as a fallback if sc.exe is not running properly, has been removed. This is not needed since this mechanism has been changed in EWA 1.18. |
QC | Title | Description |
---|---|---|
Installermanager Verbesserung der Prozessprüfung | If different TransBase-databases are installed on the system, this will no longer keep the installation process from installing or updating EWA. |
QC | Severity | Title | Description |
---|---|---|---|
Serious | Installermanager Prüfen und Stoppen von EWA Services vor Installationsdurch-führung | There were some problems with the managing of Windows Services within the installation process. These problems have been adressed and fixed now, so that the Installer Manager does not require sc.exe anymore and works also on systems with different locales. | |
Medium | Installermanager Anzeigen der zuletzt aktualisierten Versionen | The creation of the version.txt has been changed so that a problem with old version after updating should be fixed now. |
QC | Title | Description |
---|---|---|
4028 | Migration of Datacard-URL in wis_cfg.xml | The URLs to the EPC datacard to be displayed within WIS are now migrated during software-update. |
Logfiles for installation process | The logfiles for the installation process have been changed. For some cases log-entries are logged on information level, instead of Warning. Also the format of logging has been changed. |
QC | Severity | Title | Description |
---|---|---|---|
QC | Title | Description |
---|---|---|
Removal of dependence of sc.exe in installation process | For managing EWA services the installer uses sc.exe. As this is not always reliable, the dependence has been removed, so the installer will install anyway. |
QC | Severity | Title | Description |
---|---|---|---|
QC | Severity | Title | Description |
---|---|---|---|
QC | Severity | Title | Description |
---|---|---|---|
DTS | Title | Description |
---|---|---|
- none -
- none -
- none -
QC | Title | Description |
---|---|---|
QC Defect ID | Severity | Title | Description |
---|---|---|---|
Medium | Incremented Versions | The versions of the EWA-jar-files have been incremented in order to update the certificates. | |
Medium | Fixed versioning of CommonLic | The versioning of CommonLic.dll has been fixed. |
QC | Title | Description |
---|---|---|
WebService: Auslesen von Benutzer-Zugriffsberechtigungen | A new functionality for determining the user-accessrights on server-side has been integrated. This functionality needs to be activated in core_cfg.xml before using it. Therefore a password needs to be set for AccessRightsWS->Password. This password will be used to secure communication between server-internal communication and the functionality is not usable without this security being set. | |
EWANAPI - Anpassung für XENTRY Connect | EWANAPI has been extended to also be able to read appserv.ini on XENTRY Connect. | |
Tomcat64 Installer in Masterbuild integrieren | The installation package for tomcat64 has been integrated into EWA release within the contribute-directory. |
QC Defect ID | Severity | Title | Description |
---|---|---|---|
4059 | Low | [QualityCenter] - Defect: [4059] - Status: [New] - Summary: [ewanapi.exe, wis.exe und wisapi.exe haben altes Datum in Copyright-Feld] | The copyright-information of EWANAPI has been updated to current year. |
QC | Title | Description |
---|---|---|
New dataspooler | A new version of dataspooler has been integrated. It is a complete new implementation of dataspooler. |
|
EWANAPI fix for Star Diagnosis | EWANAPI has been fixed to adress an issue on Star Diagnosis when using configuration of SDnetControl. | |
4022 | [QualityCenter] - Defect: [4022] - Status: [New] - Summary: [Problem with market/manufacturer notes when a user is to be deleted] | When a user is to be deleted, the market/manufacturer notes of this user should not be deleted at the same time. They should still be available for other users to read. This has been implemented now. |
Login-Seite | On the Login-page of EWA the java version is detected. However in 32bit-Browsers a 64bit-JRE cannot be detected correctly. Therefore the errormessage has been changed. | |
Anpassung der Doku zur Installation von SQL-Servern | The documentation for installing SQL Server has been updated to better instruct how to set up the database user. | |
Release Notes Client Checker in ReleaseNotes Operations aufnehmen | The client checker version should be included within release notes. | |
AdminTool Dokumentation aktualisieren | The user guide for the AdminTool has been adopted to the new AdminTool. |
QC Defect ID | Severity | Title | Description |
---|---|---|---|
4088 | Medium | Download-Area Direct Access does not work in EPC | The generation of the URL for direct access to the Download Area was not correct, if the default port for http (80) or https (443) was configured for EWA. |
QC | Title | Description |
---|---|---|
Configure Secure Linkout in core_cfg.xml | The URL to secure linkout service has been added to the core_cfg.xml. |
QC Defect ID | Severity | Title | Description |
---|---|---|---|
4051 | Medium | Fixed displaying of access rights for groups when startkey is not valid | In case both startkeys (for WIS and EPC) are invalid, an error occured when editing a group. This has been fixed. |
QC | Title | Description |
---|---|---|
EWAnAPI Parameter ASSYST Servicescope | Introduction of new EWAnAPI parameter for ASSYST servicescope. The parameter -ssc has been integrated. | |
EWAnAPI Parameter EPC NavPath | Introduction of new EWAnAPI parameter for EPC Navication Path. The parameter -n has been integrated. | |
EWAnAPI Installer for 64bit | The installation of EWAnAPI has been changed to be platform-independent (however still only for Windows). The setup will install all files needed for 32- and 64bit-runtimes. | |
Versioning of EWAnAPI | The versioning of EWAnAPI has been updated. The third part of the version now represents the software-version of EWAnAPI (first two parts are for EWA-Release, last part is build-number). In future releases the third part of the version of EWAnAPI only changes, if EWAnAPI itself changes. | |
Versions of components in release-notes | The versions of the components of EWA are now listed in the release-notes. | |
Removal of Setting of Access rights on Star Diagnosis | On Star Diagnosis systems access rights should not be set specifically for WIS-application and database. Therefore this setting has been removed. |
QC Defect ID | Severity | Title | Description |
---|---|---|---|
4012 | Medium | Removed image from banner message popup | The image in the banner message popup window has been removed. This was not displayed correctly as it results in a horizontal scrolling bar. |
Medium | Fixed incorrect language of banner message popup | The language displayed in the banner message popup window was not determined correctly. This has been changed to be the same language as the rest of EWA-website. | |
Serious | Fixed problem with japanese characters in system news | Japanese characters were not being displayed correctly in system news on client-side (WIS or EPC). This has been fixed now, so that also japanese characters are shown. | |
Medium | Fixed displaying of access rights for groups when startkey is not valid | If a startkey has been invalidated, the access rights assigned to a group were displayed wrongly. This was confusing and has now been corrected to represent the value that it indeed configured. | |
3916 | Closing database-processes during SD-installation | During the setup on Star Diagnosis systems any running transbase-process should be closed. This ensures that updates can be installed properly. |
QC | Title | Description |
---|---|---|
AdminTool - Hooks für WIS-DB-Installation | For AdminTool 4 Hooks (similar to Installer-Hooks) are executed, if configured. The preInstall-, preAttach-, postAttach-, and postInstall-Hooks have now been fixed to work correctly in the new AdminTool. However it is not recommended to use this feature, especially for long running tasks: Tasks that are running longer then 30 seconds will be stopped by AdminTool. |
QC Defect ID | Severity | Title | Description |
---|---|---|---|
Medium | AdminTool - Fehler beim Kopieren der Romfiles führt nicht zu Abbruch der Installation | The canceling of an update when the copy-process has failed showed one wrong message. This has been fixed. | |
Medium | AdminTool - GUI wird beim Kopieren nicht aktualisiert | A minor bugfix for updating the GUI when installing a database. |
QC | Title | Description |
---|---|---|
Added write permission on Star Diagnosis | AdminTool now sets write-permissions for WIS database-files on Star Diagnosis. | |
AdminTool - Benötigten Speicherbedarf bei Auswahl des Ziellaufwerks anzeigen | The required space for the database installation of WIS or EPC is now displayed prior to installation. | |
4069 | [QualityCenter] - Defect: [4069] - Status: [New] - Summary: [Kopieren der Romfiles mit Stop vor dem integrierten Softwareupdate] | After copying romfiles from the DVD the AdminTool should stop and inform the user about the software update that is executed as next step. The user should then have the possibility to cancel the update. |
AdminTool Übernahme bereits kopierter Rom-Dateien | When installing WIS- or EPC-databases the copying of romfiles should not overwrite existing romfiles. Also when cancelling an update the romfiles should not be deleted by default. This enables users to stop and resume an update later. | |
AdminTool Optimierung des WIS-Updates bezüglich Serververfügbarkeit | EWA server and WIS database should not be stopped immediately when updating a WIS database. Only if it is necessary to stop those services (e.g. attaching new database) they will be stopped now. | |
AdminTool Vertauschte Eingabe von Startkeys abfangen | If the user enters the StartKeys in AdminTool for WIS and EPC in the wrong way this will be handled accordingly now. E.g. if a WIS-StartKey is entered as EPC-StartKey this will be stored as WIS-StartKey. | |
AdminTool Prüfung, ob Administrator-Rechte vorhanden sind | Some checks are being executed before startup of the AdminTool now. Only if all of those checks are successful the AdminTool will be started with all functionality. | |
AdminTool Abfrage des passenden WIS-Vollversion-Mediums | As for EPC all required media are requested prior to installation of the database, this procedure has been adopted to WIS-database installation. So now when installing a WIS-database the required full-version-media is needed before starting of the installation. | |
AdminTool Erweiterte Statusanzeige der Datenbankinstallation | AdminTool now displays more information about the database-installation process. Especially for EPC-Database-installation it now displays which database is being installed at the moment. | |
Expertenmodus für AdminTool | A new extended mode has been added to AdminTool. This mode is to be enabled in the menu and features software-only-updates, more details for data-updates and backup-/restore-functionality for the core database. | |
AdminTool - Aufforderung für DVDs | The requesting of media has been changed to be equal in every situation. So now AdminTool will ask for new media when checking all media and copying romfiles in the same way. |
QC Defect ID | Severity | Title | Description |
---|---|---|---|
4054 | Low | [QualityCenter] - Defect: [4054] - Status: [New] - Summary: [Warnungen zum bevorstehenden Update im Admin Tool als Information deklarieren] | Some popup messages in the AdminTool had to be declared as Warning. However this was misleading as they represent only Information. This has been fixed. |
4052 | Low | [QualityCenter] - Defect: [4052] - Status: [New] - Summary: [Admin Tool - Menüs nach dem Umschalten der Sprache sind verwechselt] | When changing the language in AdminTool some menu-items had the wrong lable. This has been fixed now. |
Medium | AdminTool Freeze nach dem Start von Netviewer | There was a problem with starting of NetViewer from within the AdminTool. This has been fixed now, so that the AdminTool is usable still while running NetViewer. | |
Medium | AdminTool - Konsistenzprüfung | There was a problem with the execution of a consistency check. This check has to be executed if the software-update includes a version change within the first three parts of the version. | |
Serious | Admin Tool Prüfen und Stoppen von EWA Services | There were some problems with the managing of Windows Services within the AdminTool. These problems have been adressed and fixed now, so that the AdminTool does not require sc.exe anymore and works also on systems with different locales. |
QC | Title | Description |
---|---|---|
QC Defect ID | Severity | Title | Description |
---|---|---|---|
3963 | Medium | EWA Admin Tool checks the available disk space | In certain cases, the check for available disk space was not done correctly. This could let the Admin Tool install a database for WIS or EPC, even if not enough disk space was available. This problem has been fixed, so that the disk space is calculated correctly. |
QC | Title | Description |
---|---|---|
QC Defect ID | Severity | Title | Description |
---|---|---|---|
3978 | Medium | Deltaupdates for EPC | After installing 2 EPC delta-updates in a row, AdminTool asked for the proper Baseline-media. However as this baseline had been installed already, this was not necessary. This has been fixed now. |
High | Fixed determination of location of romfiles for EPC | The locations of romfiles for EPC was not always determined correctly. This has been fixed. | |
4016 | Medium | AdminTool freezes during cleanup steps | The calls of database- and service- administration-processes have been changed to have a timeout. This will help the AdminTool not to get stuck when not receiving answers of the called processes. |
High | Deletion of old database-versions on Star Diagnosis | On Star Diagnosis systems old database-versions still remained on the hard-drive. This has been fixed, so that old versions are deleted correctly and only files that are still needed remain. |
DTS | Severity | Title | Description |
---|---|---|---|
DTS | Severity | Title | Description |
---|---|---|---|
QC | Title | Description |
---|---|---|
- | Signature Version | The signature version has been changed from 1.15 to 1.16 |
- | WIS Config Value Migration | The values for datacard-URL and Annahmeblatt will now be migrated from existing wis_cfg.xml |
QC | Severity | Title | Description |
---|---|---|---|
- | - | - | - |
QC | Prio | Title | Description |
---|
QC | Title | Description |
---|---|---|
- | - | - |
QC | Severity | Title | Description |
---|---|---|---|
- | High | Webservice User-DB Access | The Webservice access to the wis/asra user setup will now work for new users with uninitialized setup-data |
QC | Prio | Title | Description |
---|
QC | Title | Description |
---|---|---|
4107 | Language dependent joborder.txt | The joborder will now be stored language dependent in ISO 8859-x |
4096 | New Webservice | New webservice for getting asra vehicle data and asra operation items |
QC | Severity | Title | Description |
---|---|---|---|
4110 | High | Configuration of Annahmeblatt | The Annahmeblatt functionality may now be diasabled in wis_cfg.xml |
QC | Prio | Title | Description |
---|
QC | Title | Description |
---|---|---|
- | MSS Annahmeblatt | A new step has beed added in MSS for printing an Annahmeblatt |
4084 | Ambibous Vehicletypes | The processing of vehicles which differ only in the vehicle type has been improved |
4081 | Lucene Analyser Update | The Lucene Analyser has been updated to Version 3.6.1 |
QC | Severity | Title | Description |
---|---|---|---|
4086 | High | Improved Document Parser | Documents will now be shown even if there are invalid tabulator |
4090 | Low | Improved Document Processing | Missing Documents will no longer lead to NullPointerException |
- | High | Lucene Indexer | The Lucene Indexer will also work in UNIX shell |
QC | Prio | Title | Description |
---|
-
DTS | Title | Description |
---|
-
DTS | Severity | Title | Description |
---|---|---|---|
QC4131 | 2 | Filter issue - chassis Ident in Aggregate Footnote |
DTS | Title | Description |
---|---|---|
QC | Replace background images | |
QCR | Enable mutliple Class select for FIN entry |
-
DTS | Severity | Title | Description |
---|---|---|---|
QC4123 | 2 | EPC hangs by using type 278 or 135 | |
QC4085 | 2 | Plant code only handling not working correctly | |
QC4037 | 2 | Orphan notes tool never finish with errors in the log | |
QC3987 | 2 | Hide aggregate catalogs which are not valid for chassis class |
DTS | Title | Description |
---|---|---|
QCR | Exclude list of remanufactured aggregates need extension 0T, 1T, 2T | |
QCR | Aggregate Filtering Phase 1 | |
QCR 227 | Wildcard Partnumber search | |
QCR 239 | Auto-Nav-Path-XSF-EPC | |
QCR 260 | CKD Ident Filter | |
QCR 261 | Spring partnumbers on datacard |
-
DTS | Severity | Title | Description |
---|---|---|---|
QC4100 | 2 | In Japanese can some SA not be open | |
QC4099 | 2 | Sometimes in Japanese are footnotes not readable | |
QC4094 | 2 | Shoplist quantity field with value NB or - popup window | |
QC4092 | 2 | Unexpected behaviour of WMI field (WD0) | |
QC4087 | 2 | SA numbers missing in export Hit List - Search for part w/o vehicle data | |
QC4049 | 2 | Last 8 digits dialog is not wide enough for some titel languages | |
QC4048 | 2 | Keybourd shortcut opens the wrong window | |
QC4047 | 2 | Datacard disabled icon is wrong after F3 when datacard note exists | |
QC4046 | 2 | Notes for a subgroup are shown by clicking on a subgroup thumbnail | |
QC4045 | 2 | BM Note reset issue as normal user | |
QC4038 | 2 | Log entry get created for special user "epc" not matching "EPC" | |
QC | 2 | Hit List contains Html code for colored characters. |
-
DTS | Severity | Title | Description |
---|